Dynamech 5.4 MVA power transformer with radiator banks and marshalling box

Power Transformers
up to 10 MVA, 33 kV.

Three-phase, oil-immersed power transformers for substations, renewable plants and heavy industry — designed to IS 2026 / IEC 60076 and tested in our Bhopal works before dispatch.

RATING
≤ 10 MVA
VOLTAGE CLASS
≤ 33 kV
COOLING
ONAN / ONAF
STANDARD
IS 2026
TECHNICAL SPECIFICATION

Built to your specification.

Losses, impedance, vector group and tapping range are designed to your specification or tender GTP. Send your requirement and we will return guaranteed technical particulars with the offer.

REQUEST GTP & OFFER
PARAMETERDYNAMECH POWER TRANSFORMER
RatingUp to 10 MVA
Primary voltageUp to 33 kV class
PhasesThree-phase
Typical voltage ratios33/11 kV · 33/0.433 kV · 11/0.433 kV · others on request
CoolingONAN · ONAF · OFWF
Winding materialElectrolytic grade copper
CoreCRGO, step-lap construction with mitred joints
Insulating fluidMineral oil · silicone oil · natural ester · vegetable-based oil
Losses & impedanceAs per customer specification / tender GTP
Vector group & tappingsAs per customer specification
Ambient conditionsDesigned for extreme system supply and ambient temperatures
Applicable standardsIS 2026 · IEC 60076 · ANSI · BS · AS · SABS
FITTINGS & PROTECTION

Standard fittings.

Protection and monitoring for oil level, gas detection, pressure and temperature. Final scope is confirmed against your specification.

  • Conservator with magnetic oil level gauge
  • Buchholz (gas detection) relay
  • Oil and winding temperature indicators
  • Pressure relief device
  • Silica gel breather
  • Detachable radiator banks
  • Marshalling box
  • HV / LV bushings or cable boxes
  • Rating and diagram plate
  • Lifting lugs, jacking pads and rollers
STANDARDS

Applicable standards.

IS 2026Indian Standard for power transformers — design, rating and testing
IEC 60076International standard for power transformers
IS 335New insulating oils for transformers (mineral oil option)
ANSI · BSAmerican and British specifications on request
AS · SABSAustralian and South African specifications on request
TESTING & QUALITY

16 tests. Documented before dispatch.

Every transformer is tested in our works to IS 2026 and IEC 60076 by qualified engineers with precision instruments. Test certificates accompany each unit; type and special tests are performed as agreed with the customer.

TESTCATEGORY
Insulation Resistance & PIROUTINE
Voltage Ratio MeasurementROUTINE
Vector Group & PolarityROUTINE
Winding ResistanceROUTINE
No-Load Loss & Magnetising CurrentROUTINE
Load Loss & Impedance VoltageROUTINE
Separate Source Voltage WithstandROUTINE
Induced Over Voltage WithstandROUTINE
Oil Dielectric Strength (BDV)ROUTINE
Magnetic BalanceROUTINE
Temperature RiseTYPE
Pressure & Vacuum TestTYPE
Zero Sequence ImpedanceSPECIAL
Tan DeltaSPECIAL
Partial DischargeSPECIAL
Paint AdhesionADDITIONAL
REFERENCE PROJECT

5.4 MVA, from Bhopal to site.

Built and tested at our works, shipped with radiators detached on a hydraulic trailer, and erected at a renewable energy site in Ujjain division, Madhya Pradesh.

5.4 MVA power transformer with radiator banks loaded for dispatch01 · DISPATCH
5.4 MVA power transformer in transit on a hydraulic trailer02 · TRANSIT
5.4 MVA power transformer erected at site03 · ERECTED ON SITE
FAQ

Power transformer questions.

What is the maximum rating of a Dynamech power transformer?

Dynamech builds three-phase power transformers up to 10 MVA with primary voltage up to 33 kV. Inverter duty transformers for solar plants can be built up to 13.2 MVA.

Which standards do Dynamech power transformers comply with?

Power transformers are designed and tested to IS 2026 and IEC 60076. Designs to ANSI, BS, AS and SABS specifications are available on request.

Which cooling and insulating oil options are available?

Cooling can be ONAN, ONAF or OFWF. Units can be filled with mineral oil, silicone oil, natural ester or vegetable-based oil as per requirement.

Can losses and impedance be designed to our specification?

Yes. No-load loss, load loss and percentage impedance are designed to the customer's specification or tender GTP, and verified by routine tests before dispatch.